Life Science Solutions
应用资料

Dynamic Volumetric Imaging with the FV3000RS Confocal Microscope: 3D Reconstruction of Actin Dynamics in a Colletotrichum graminicola Spore


Colletotrichum graminicola is a widespread fungal pathogen and a major disease-causing agent of cereal crops, including wheat and corn. In corn, fungal infections of C. graminicola cause anthracnose leaf blight, resulting in severe crop damage and major economic losses for farmers. Understanding the cytoskeletal dynamics in germinating C. graminicola spores could therefore contribute to the prevention of disease.

Pregermination Organization of Filamentous Actin Cables

In this experiment, the FLUOVIEW FV3000RS microscope was used to study the actin dynamics of a C. graminicola spore prior to germination. Filamentous actin cables can be observed within a crescent-shaped spore that has yet to germinate. The cables have organized to extend lengthwise across the spore at the plane of contact with the surface. The actin cables can be seen retracting from the center towards either end of the spore.

Loading the player…
/data/Image/Application/3d-Actin-Dynamics/3d-actin-dynamics-fig-1.mp4

Figure 1: XYZT reconstruction of actin dynamics in a spore of C. graminicola before germination.

Imaging conditions
Objective: 100X oil 1.49NA TIRF objective (UAPON100XOTIRF)
Microscope: FLUOVIEW FV3000RS laser scanning confocal microscope
Lasers: 488 nm (GFP, green), 561 nm (DIC, gray)
Scanner: Resonant scanner
XY frames: 0.272 sec/frame
Z series: 22 steps (6 sec/section)
T series: 30 Z stacks acquired over 3 minutes

Observation of Two Distinct Cytoskeletal Events during Germination

Following the organization of actin into cables, the germination process of a C. graminicola spore is marked by two successive cytoskeletal events, with the formation of both patches and cables during both events. In the first event, the cytoskeleton rearranges to form a septum that delineates the fungal spore into two distinct cells (depicted by the medial barrier across the width of the spore). Following the septation event, actin cables form at the site of germination and extend into the developing germ tube toward the apex. These two events can be seen in Figures 2 and 3.

Loading the player…
/data/Image/Application/3d-Actin-Dynamics/3d-actin-dynamics-fig-2.mp4

Figure 2: XYZT of cross-wall formation during a septation event in a germinating spore of C. graminicola, followed by the formation of a germ tube.

Imaging conditions
Objective: 100X oil 1.49NA TIRF objective (UAPON100XOTIRF)
Microscope: FLUOVIEW FV3000RS laser scanning confocal microscope
Lasers: 488 nm (GFP, green), 561 nm (DIC, gray)
Scanner: Resonant scanner
XY frames: 0.470 sec/frame
Z series: 31 steps (5.35 sec/stack)
T series: 34 Z stacks acquired in 1-minute intervals over 33 minutes

Loading the player…
/data/Image/Application/3d-Actin-Dynamics/3d-actin-dynamics-fig-3.mp4

Figure 3: 3-D reconstruction of the actin cytoskeleton in a germinating spore of C. graminicola, in which the developing germ tube can clearly be seen.

Imaging conditions
Objective: 100X oil 1.49NA TIRF objective (UAPON100XOTIRF)
Microscope: FLUOVIEW FV3000RS laser scanning confocal microscope
Lasers: 488 nm (GFP, green), 561 nm (DIC, gray)
Scanner: Galvano scanner
Z sections: 17 steps


How the FV3000 Confocal Microscope Facilitated Our Experiment

Maintaining Focus during 4-Dimensional Time-Lapses with Olympus’ TruFocus Z-Drift Compensation System

The advanced TruFocus Z-drift compensation system (ZDC) facilitates the acquisition of multiple sequential Z stacks with no drift in the Z dimension. This enables users to generate clear, focused, and continuous time lapses in three dimensions, which enables researchers to interrogate protein dynamics in the entire sample without concern for Z-drift.

Rapid Four-Dimensional Acquisition with the Resonant Scanner

The FV3000RS microscope features a high-performance resonant scanner that enables rapid acquisition time-lapses of live-cell dynamics. The resonant scanner in the FV3000RS microscope also maintains a full 1X field of view with FN 18, with imaging speeds of 30 frames per second at 512 × 512 pixels. Using the resonant scanner, researchers can acquire Z stacks of numerous planes in seconds, achieving high-resolution Z stacks of rapidly occurring phenomena in live cells.

TruSpectral GaAsP Detectors Provide High Sensitivity for Live Cell Imaging

Integrated in all FV3000 confocal microscopes, TruSpectral detection technology enables higher light throughput compared to conventional spectral detection units. The volume phase hologram diffracts light with an up to three-fold higher transmission efficiency than reflection gratings. When combined with high-efficiency GaAsP PMTs, the FV3000 microscope’s high-sensitivity spectral detector (HSD) requires minimal laser power to obtain high signal-to-noise images, enabling powerful yet gentle live cell imaging.


Comment by Joseph Vasselli and Dr. Brian Shaw

Our research has the goal of understanding the role of the cytoskeleton and endocytic proteins in growth and development in filamentous fungi. Tracking the spatiotemporal localization of these proteins during shifts in growth polarity is crucial to our experiments. The FV3000 microscope’s superb Z-drift compensation, high-sensitivity detectors, and rapid resonant scanner enables us to acquire high-resolution XYZTs to effectively interrogate the dynamics of these proteins in live cells.

Vasselli at microscope


Acknowledgments

This application note was prepared with the help of the following researchers:

Dr. Brian D. Shaw

Dr. Brian D. Shaw, Professor, Fungal Biology, Department of Plant Pathology and Microbiology, Texas A&M University

Joseph Vasselli

Joseph Vasselli, Graduate Student, Department of Plant Pathology and Microbiology, Texas A&M University

Products used for this application

激光扫描共聚焦显微镜

FV3000

  • 可提供配置常规扫描的FV3000或配置常规/共振混合扫描的FV3000RS
  • 所有通道均可进行全新高效且精确的全真光谱TruSpectral检测
  • 针对活细胞成像的高灵敏度和低光毒性优化
  • Inverted and upright frame options to suit a variety of applications and sample types
用于超高分辨率成像或全内反射成像的高分辨率物镜

APON-TIRF/UAPON-TIRF/UPLAPO-HR

  • 高数值孔径为高对比度要求的全内反射成像或超高分辨率成像提供极佳的消失波
  • HR系列物镜是世界首款*高平场性下数值孔径达到1.5的平场复消色差物镜。

* 根据奥林巴斯的研究,截止至2018年11月

Z Drift Compensator

IX3-ZDC2

  • 随时保持焦点
  • 易用性设计
  • 专为活细胞影像设计
  • 通过cellSens软件实现高精度,多区域成像

已经成功添加到您的书签

查看书签关闭

Maximum Compare Limit of 5 Items

Please adjust your selection to be no more than 5 items to compare at once

对不起,此内容在您的国家不适用。